Tip sa Pagbayad: | T/T,Paypal,Money Gram,Western Union |
---|---|
Incoterm: | FOB,CIF |
Min. Order: | 1 Set/Sets |
Model No.: HLG-150H
Brand: Kahulugan
Pagputos: Karton
Pag-uswag: 20000pcs per month
Transportasyon: Ocean,Land,Air
Dapit sa Sinugdanan: Guangdong, China
Abilidad sa Supply: 5000pcs per month
Port: Shenzhen,Guangzhou,Hongkong
Tip sa Pagbayad: T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CIF
Ang HLG-150H nga gipasabut nga waterproof gipangulohan ang suplay sa kuryente
Deskripsyon sa mga Produkto
WaterProof 150W usa ka output nga pagpugong sa suplay sa kuryente , Ang mosunud nga modelo kaylap nga gigamit sa mga lampara sa ISELED ` S. HLG - 150 H - 12 , HLG-150 HLA 50 HLA
HLG-150 H -12 blangko: Ang IP67 gimarkahan. Cable alang sa akong koneksyon.
HLG-150 H -12A: IP65 RATED. Ang output nga boltahe ug kanunay nga lebel sa karon mahimong i-adjust pinaagi sa internal nga potenterometer.
HLG-150 H -12B: Ang IP67 gimarkahan. Ang kanunay nga lebel sa karon nga lebel pinaagi sa output cable nga adunay 1 ~ 10VDC o PWM signal o resistensya.
HLG-150 H -12D (kapilian): IP67 nga gimarkahan. Timer Dimming Function, Kontaka ang Kahulugan Maayo alang sa mga Detalye.
Model |
HLG-150H-12 |
HLG-150H-15 |
HLG-150H-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
|||
7.5-12.5A |
6-10A |
3.8-6.3A |
||
RATED POWER |
150W |
150W |
151.2W |
|
VOLTAGE ADJ. RANGE |
10.8-13.5V |
13.5-17V |
22-27V |
|
Input |
Voltage Range |
90-264VAC 127-370V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
92% |
92.5% |
93.5% |
|
AC CURRENT (Typ.) |
1.7A / 115VAC 0.75A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14-17V |
18-21V |
28-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
100 ℃ up or less10 ℃ (RTH2) |
|||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down |
||||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
192.2K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
228*68*38.8mm (L*W*H) |
|||
PACKING |
1.15Kg; 12pcs/14.8Kg/0.8CUFT |
|||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Type A only. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. |
1. Ang tanan nga mga parameter nga dili espesyal nga gihisgutan gisukod sa 230vac input, gimarkahan nga pagkarga ug 25 sa temperatura nga ambient. Kwarta
2. Ang Ripple & Saba gisukod sa 20mhz nga bandwidth pinaagi sa paggamit sa usa ka 12 nga "baliko nga pares-wire nga natapos sa usa ka 0.1UF & 47UF nga managsama nga capacitor.
3. Pagkamaayo: Naglakip sa pagtakda sa pagtugot, regulasyon sa linya ug regulasyon sa pagkarga.
4. Ang pag-apil mahimong kinahanglanon sa ilawom sa mga ubos nga boltahe sa pag-input. Palihug susihon ang static nga mga kinaiya alang sa dugang nga mga detalye.
5. I-type ang usa ra.
6. Ang laraw sa kaluwasan ug EMC nagtumong sa En60598-1, CN15233, GB7000, FCC Part18.
7. Ang gitas-on sa gitakda nga oras gisukod sa bugnaw nga una nga pagsugod. Ang pag-on / gikan sa suplay sa kuryente mahimong mosangput sa pagtaas sa set sa oras.
8. Ang suplay sa kuryente giisip nga usa ka sangkap nga pag-operate sa kombinasyon sa katapusang kagamitan. Sukad nga ang pasundayag sa EMC maapektuhan sa Kompleto nga pag-instalar, ang mga katapusang kagamitan sa mga tiggama kinahanglan nga kwalipikado nga kwalipikado sa EMC nga direktiba sa kompleto nga pag-instalar pag-usab.
9. Sultihi ang pahayag sa garantiya.Mga kategoriya sa produkto : Mga Accessories > MAGPANGITA SA WATERWEWEWEW SOUNTPROOF POWER Supply
Subscribe To Our Newsletter:
Get Updates, Discounts, Espesyal
Nagtanyag ug Mga Big Prize!